Auto Hematology Analyzer model: TEK-5000P
Technical Specifications:
- 3 Diff of WBC Double Chambers for WBC and RBC/PLT
- 21 PARAMETERS (WBC, LYM#, MID#, GR#, LYM%, MID%, GR%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCC, P-LCR)
- 3 HISTOGRAM (WBC, RBC, PLT)
- Sample Types: Whole Blood, Peripheral Blood, Predilute
- Sample Volume: Whole Blood, Peripheral Blood10μL, Predilute 20μL
- Storage Capacity: Auto-save, more than 200,000 analysis results available
- Throughout: 60 tests / hour
- Data Search Mode: By Sample ID, Patient ID, Date, Multi-keywords. Loading/extracting data, offline reading
- Display: 10.4 inch colorful touch screen
- Operation Mode: Touch screen, Keyboard/mouse
- Quality Control: L-J. X-R, X-B, etc
- Printout: Thermal printer (defaulted), available for external printers Optional printing templates and format
- Data Communication: LIS, HL7
- Wireless Connection: Wifi, Bluetooth
- Ports: LAN x 1, RS232 x 1, HDMI x 1, USB Port x 4
- Dimension & Weights: 440 x 350 x 440 mm, 17 kgs
- Power Supply: 110-240 V, 50/60Hz
ใบรับแจ้งรายการละเอียด เลขที่ 65-2-2-1-0001370
*อ่านคำเตือนในฉลากและเอกสารกำกับเครื่องมือแพทย์ก่อนใช้*
-----------------------------------------------------------------
Warning:
- The operator is obliged to comply with the local and national regulations on the discharge and treatment of reagents, waste liquid, waste samples, consumables, etc.
- The reagent can irritate the eyes, skin and mucous membranes. When contacting reagent related articles in the laboratory, the operator shall comply with the laboratory safety operation regulations and wear personal protective equipment (such as laboratory protective clothing, gloves, mask, etc.).
- Once the reagent comes into contact with the skin, wash it with plenty of water immediately. If necessary, ask a doctor for treatment. Once the reagent contacts the eyes, rinse it with plenty of water and receive medical treatment.
- Clothes, hair, hands, etc. must be kept at a certain distance from moving parts to prevent being pinched by moving parts.
- The sampling needle is relatively sharp, and the blood sample, quality control material and calibrator that may be carried on the sampling needle have potential biological hazards, so avoid contact with the sampling needle.
Precautions:
- Please check the firmness of all the doors and covers before running the analyzer.
- Make sure all the safety measurements are adopted. Disable any safety device or sensor is prohibited.
- Please take action to any alarm and problem indication immediately.
- Do not touch the moving parts.
- Contact TECOM or TECOM-authorized distributors in time if any damaged part is found.
- Be careful when opening /closing and removing/installing the doors,covers and boards of the analyzer.
- Discard the analyzer according to government regulations.
Contraindication: N/A